SmartGage

SmartGage

Key Features

  • IOT Ready LVDT Gauging Display
  • On-Screen On-Line SPC DRO
  • Auto Offset Compensation
  • PDF Reports On Screen
Input Channels Max 8 LVDT
Applications Standard
Dimension Type Linear
Resolution 0.1µm/ 1µm
Units mm
Measurement Modes Current, Min, Max, TIR, AVG
Additional results      Max, Min, Ovality, and Taper for respective result can be display in run mode as additional results.
Result Formula Editor Result formula can be edited for combinations of Piezo channels and / or other results.
Indications              Pass, Fail, Warning with facility to select require display reading in require colour according to the tolerance band
Grade Max 25 Grades available
Other Features        Machine Stop Massage and Machine stop signal available for reject job condition
 

 

Calibration

Single/Double Master configurable
Force Mastering after N number of measured jobs.
Group Calibration for selected result in one group.
Auto Mastering is available. Accept Higher and Lower master on inserting into fixture/plug automatically in calibration process
 

Measurement process

Auto Cycle (After inserting job in Fixture/Plug it will show related Fixture/Plug result)
Measurement Cycle (Sequential measurement)
 

Charts                       

XBar- R Chart/ XBar- S Chart
Histogram
Runchart
 SPC values Cp, Cpk, Pp, Ppk
 Counters Over Size
Under Size
OK
Not Good
Total measure
Total produces (After receiving Cycle complete signal from Machine)
Setup 100nos can be created.
Number Of Results 64
User Interface     7” touchscreen Colour LCD display  (PIXEL: 800 x 480 – RGB)
 

Ports        

1. RS-232 for PC communication
2.RS-232 for machine interface (compatible Fanuc o-i Power mate/16/18 series)
USB USB2.0 Compliant (For Mass Storage Device).
Ethernet Ethernet for sending reports to server using Client server utility
Digital Outputs  7 outputs, Isolated, Open collector
Digital Inputs 8 Inputs, Isolated
Display Views    Digital Readout/ Dial / Run Chart
Memory              In built micro SD card of 16GB for data storage
Footswitch interface Available
Login Operator and Supervisor login (Limited menu access to operator)
Report Storage Shift wise data storage
Report Format PDF, CSV, and DFQ (to view in Q-DAS application).
In SmartGage we can only view PDF format file.
All report is available in Year ->Month->Date->and Setup wise format.

Product Enquiry