Gauging Display 4V1002

4V1002

Key Features

  • Number of Channels: 2-LVDT or 1-PIEZO
  • 4″ touch Colour display with dial, dro and run chat
  • Cp, Cpk, (Can be seen on Display of ongoing Measurements as per Subgroup size 10 by default)
  • 16 GB Inbuilt data storage
  • Data storage facility
Feature Description
Number of Channels 2-LVDT or 1-PIEZO
Number of results 2 (Max)
Number of Setups 10 (Max)
Number of Layouts 2 (Max)
Inbuilt data storage 16 GB
Hardware Keys 6 Navigation Keys
Result Views Dial, DRO, Run-Chart
Measurement Modes Current, Minimum, Maximum, Average, Difference
Dimension Types Linear
Linear units MM, Micron, INCH
Linear Resolution 0.1, 0.2, 0.5, 1, 2, 5, 10 Micron
Users Quality Admin and Operator Login can be created. Max. 10 users limit. (Minimum access to Operator Login)
Digital Outputs 3 Digital Outputs Available (OK, Reject, Rework). Open Collector Outputs
Digital Inputs NA
Foot-Switch 1 Foot-Switch Connection Available
Communication Ports 1xRS232 (COM1), 1xEthernet, 1xUSB
Formula Editor Result formula can be edited for combinations of Channels and or other results
Preset And Mastering Step, Simultaneous (Group)
Tolerance Entry Nominal, Lower Set Limit (LSL), Lower Control Limit (LCL), Upper Control Limit (UCL), Upper Set Limit (USL)
SPC Cp, Cpk, (Can be seen on Display of ongoing Measurements as per Subgroup size 10 by default)
Run-Chart Run-Chart of ongoing Measurement cab be seen on Screen
Job Counters Total Jobs, OK Jobs, NG Jobs. Separate screen for result wise job counters display
 

Measurement Delays

Start-up Delay (0.1 to 9.9 Sec Stabilizing Time),

Dynamic Timer Delay (0.1 to 999.9 Sec Time for Actual Measurement after which Data will be Saved)

Measurement Cycle Auto Cycle (Auto Time Base) and Measurement Cycle (Trigger Based)
Additional Displays 4 additional displays for both results (Configurable to MAX, MIN, AVG, DIFF, Cp, Cpk)
Shortcuts on Main Screen Shortcuts for Setup, Clock Settings and Results. Need to long press for 2 seconds (only for Quality Login)
Serial Output String Standard
CSV Files For every measurement unit will send csv file to server (SmartServer Utility) and also update day-wise csv file of every Setup.
CSV files sharing to USB Drive Generated csv files can be copied to USB Drive (Pen Drive) manually
Setup Files Restore/Backup All Setup Files in Unit Can be Shared to USB Drive (Pen Drive) as backup, or Setups from other Similar Unit can be Loaded/Restored to this Unit
Auto data transfer After Completion of Measurement (Each Time) Measured Data will be Transferred to Serial Port without any External Trigger
 

Auto Air Cut-Off

Optional on Extra Charge (Contact Supplier) (Air will be in full consumption while measurement while out of Measurement consumption will be cut by approx. 80 to 90%)
Low Pressure Indication Optional on Extra Charge (Contact Supplier/Manufacturer)
Wi-Fi, Bluetooth Optional on Extra Charge (Contact Supplier/Manufacturer)
GSM for SMS facility Optional on Extra Charge (Contact Supplier/Manufacturer)
Fanuc Communication Optional on Extra Charge (Contact Supplier/Manufacturer) for Auto-Offset Function through Serial Communication (RS232)
RS-485 Optional on Extra Charge (Contact Supplier/Manufacturer) for Auto-Offset Function through BCD Communication (Digital IO’s)

Product Enquiry