Safe measurement at high voltage potentials up to 1 kV
Dynamic current and voltage measurement for automotive hybrid or electrical power train with CAN data output
Two measuring channels, usable for current or voltage measurement
Easy use of the measurement technology for various applications
Capabilities
Use in laboratories and automotive: – Measuring current and voltage in DC circuits – Measuring current and voltage in AC circuits, also with RMS value calculation
Concept
KLARI-FOUR 1000V is galvanically isolated up to 1000 V DC between measuring circuit and data output and between the four measuring channels
Each measuring channel is equipped with an ASIC and a dsPIC. Each ASIC has 5 measuring ranges and autorange function
Version
3 HE 19“ compact measurement module in Europe format, 100 x 160 mm. For electrical isolation each measuring channel plus ASIC and µC is complete solitary grouted. The data output is transmitted via isolated CAN optocoupler
Optimal adaption to the measuring task by a number of pluggable PROBES for current, voltage and temperature measurements with automatic PROBE identification
Manifold configuration possibilities via PC. The corresponding configuration can be stored in the measuring module
Your benefit
Safe measurement based on 1 kV isolation.
Variable measuring periods via 4 CAN-channels with max. 8000 frames/channel/sec
Safe measurement based on 1 kV isolation
Investment protection by easy adaption of the measuring technology to different measuring tasks
Precise and reproducible measured values in every measuring range by +/-15 bit resolution
Correct measurement results by automatic PROBE-identification with calibration value transmission
Easy implementation of CAN data export in common CAN loggers and analysis tools via supplied CAN data base