Input Channels |
1/2/3/4/5/6/7/8 LVDT |
Applications |
Standard Interface to Fanuc controller O-i / Power Mate / 16 / 18 Series for auto offset correction (Optional) Interface to Siemens CNC controller for auto offset correction (Optional) |
Dimension Type |
Linear/Angular |
Resolution |
0.1µm/ 1µm |
Units |
mm |
Measurement Modes |
Current, Min, Max, TIR, AVG |
Additional results |
Max, Min, Ovality, and Taper for respective result can be displayed in run mode as additional results. |
Result Formula Editor |
Result formula can be edited for combinations of LVDT channels and / or other results. |
Indications |
Pass, Fail, Warning with facility to select require display reading in require colour according to the tolerance band |
Grade |
Max 25 Grades ava ilable |
Other Features |
Machine Stop Message and Machine stop signal available for reject job condition |
Calibration |
Single/Double Master configurable |
Calibration |
Force Mastering after N number of measured jobs. |
Group Calibration for selected result in one group. |
|
Auto Mastering is available. Accept Higher and Lower master on inserting into fixture/plug automatically in calibration process |
|
Measurement process |
Auto Cycle (After inserting job in Fixture/Plug it will show related Fixture/Plug result) |
Measurement Cycle (Sequential measurement) |
|
Charts |
XBar- R Chart/ XBar- S Chart |
Histogram |
|
Runchart |
Online SPC |
Cp, Cpk, Pp, Ppk, Sigma |
|
Counters |
Over Size |
|
Under Size |
||
OK |
||
Not Good |
||
Total measure |
||
Total produce (After receiving Cycle complete signal from Machine using digital input signal) |
||
Setup |
99 nos can be created. |
|
Number Of Results |
32 |
|
Display |
7” touchscreen Colour LCD display |
|
Ports |
1. RS-232 for PC communication |
|
2.RS-232 for machine interface (compatible Fanuc o-i Power mate/16/18 series) |
||
USB |
USB2.0 Compliant (For Mass Storage Device). |
|
Ethernet |
Ethernet for sending reports to server using Client server utility |
|
Digital Outputs |
7 outputs, Isolated, Open collector |
|
Digital Inputs |
8 Inputs, Isolated |
|
Display Views |
Digital Readout/ Dial / Run Chart |
|
Memory |
In built micro SD card of 4GB for data storage (Contact manufacturer for additional storage capacity) |
|
Footswitch interface |
Available |
|
Login |
Operator and Supervisor login (Limited menu access to operator) |
|
Report Storage |
Date/Shift wise data storage |
|
Report Transmission |
Ethernet LAN/ WI-FI (Need to purchase WI-FI Dongle)/ USB |
|
Report Format |
PDF, CSV, and DFQ (to view in Q-DAS application). |
|
In T7V we can only view PDF format file. |
||
All report is available in Year ->Month->Date->and Setup wise format. |
Address : Survey No. 143/1/D,Milkat No. 2450/1, Village Vadgaon - 412106, Tal.: Maval, Dist.: Pune, Maharashtra, India |
Office: +91-7722020796 Sales: +91-7447797456 |